Cover: Multi-scale 3D virtual histology via phase-contrast X-ray tomography with synchrotron radiation
Jasper Frohn
Multi-scale 3D virtual histology via phase-contrast X-ray tomography with synchrotron radiation
ISBN: 978-3-863-95601-1
136 Seiten | € 47.00
Buch [Taschenbuch]
Erscheinungsdatum:
01.11.2023
Sonstiges
Jasper Frohn

Multi-scale 3D virtual histology via phase-contrast X-ray tomography with synchrotron radiation


To this day, the standard method for investigating biological tissue with cellular resolution is the examination under a light microscope, first denoted as histology by Karl Meyer in 1819. Despite the enormous success and importance of histology, it has two major disadvantages. Firstly, the specimen must be physically cut into thin sections due to the limited penetrating power of optical light, and secondly, additional staining of the specimen is required to achieve sufficient image contrast. Both disadvantages can be overcome by the non-destructive method of propagation-based X-ray phase-contrast tomography. While the mechanism of phase-contrast provides sufficient image contrast to image single cells, a tomographic imaging scheme with penetrating X-rays allows for an undamaged sample by virtually slicing the reconstructed 3D sample volume. In this work, the holotomography setup of the synchrotron endstation „GINIX“ (The Göttingen Instrument for Nanoscale-Imaging with X-Rays) was extended to a multi-scale X-ray phase-contrast tomography setup suitable for 3D virtual histology by adding two acquisition schemes. Compared to the existing setup, the first additional scheme is a propagation-based microtomography setup, which enlarges the reconstructed 3D volumes by a factor of approx. 64 at a fraction of the acquisition time (ca. 2 min). The second additional scheme aims for higher resolutions. To this end, the X-ray waveguide illumination was combined with photon counting detector with a large field of view and a novel phase reconstruction scheme, which is based on iterative farfield phase retrieval without an „empty-beam correction“ in the detector plane.

Unterstütze den lokalen Buchhandel

Nutze die PLZ-Suche um einen Buchhändler in Deiner Nähe zu finden.

Postleitzahl
Veröffentlichung: 01.11.2023
Höhe/Breite/Gewicht H 24 cm / B 17 cm / -
Seiten 136
Art des Mediums Buch [Taschenbuch]
Preis DE EUR 47.00
Preis AT EUR 48.40
Reihe Göttingen Series in X-ray Physics 30
ISBN-13 978-3-863-95601-1
ISBN-10 386395601X
EAN/ISBN

Diesen Artikel teilen

0 Kommentar zu diesem Buch

.... weitere Publikationen von Universitätsverlag Göttingen

European Sourcebook of Crime and Criminal Justice Statistics – 2021
Inhalte von Predigten im radikalislamischen Milieu
Leitfaden zur Erstellung barrierefreier Lehrvideos im universitären Kontext
Niedersächsischer Demokratie-Monitor 2021
Nordhorner Volksfront?
Politik und Recht erleben, Zukunft mitgestalten
Religiöser Wandel in muslimischen Gesellschaften
Tunesien
Wissenschaft – Ausbildung – Politik
„Individual Pieties“ und „Non-Pieties“
Nächstes Buch
Panda-Pand
Image